Globe initiates production of concentrate for pilot plant
Released
Released
Announcement PDF
Globe Metals & Mining Limited
ABN 33 114 400 609
45 Ventnor Avenue
West Perth WA 6005
ASX: GBE
+61 8 6118 7240
info@globemm.com
globemm.com
ASX Announcement
12 March 2024
Globe initiates production of concentrate for chlorination
refinery pilot plant
Highlights
•
Completion of successful flotation economic optimisation testwork to finalise choice of
reagents.
•
Production of concentrate feedstock initiated for Globe’s chlorination refinery pilot plant.
•
Construction of chlorination refinery pilot plant commences utilising technology with low
environmental impact.
Globe Metals & Mining Limited (ASX: GBE) (“Globe” or “Company”) is pleased to announce the results
of its flota�on economic op�misa�on testwork and the ini�a�on of produc�on of concentrate
feedstock for its chlorina�on refinery pilot plant.
Flota�on of Bulk Sample
In preparation for the pilot plant operation, Globe has completed a series of reagent optimisation tests
to confirm that the most efficient and cost-effective reagents have been selected. The outcome of the
testwork indicates that the collector/promoter (sourced from Mexico) in the historical testwork proved
to be a better overall economic option (expressed as consumption times cost) to reagents sourced from
South Africa.
Globe is now in the process of producing the required concentrate feedstock from the 10-tonne ore
bulk sample taken from the Kanyika mine site 1 and is pleased to confirm that the production of
niobium/tantalum concentrate via flotation follows the results of locked cycle tests carried out
internally in 2022.
It must be noted that the niobium content of the ore at this location is lower than the overall resource
grade and lower than that anticipated for the initial mining. The lower head grade reduces the amount
of pyrochlore that can be recovered per tonne of ore, which results in a recovery versus grade
optimisation.
Two scenarios were tested to show recovery optimisation versus concentrate grade optimisation. The
results of the tests are set out in Table 1. The two results are effectively the two extremes that could be
followed during flotation. The Locked Cycle Test (see Table 2) carried out on core material lies between
1 Refer to ASX Announcement titled ‘Globe extracts 10-tonne sample from Kanyika Niobium Project’ made on 3
May 2023
these two extremes. It should be noted that with the carbochlorination refining route that is relatively
insensitive to concentrate grade, Globe will be targeting high recovery at the expense of grade.
Item
Run 1: Nb2O5 recovery
optimised
0.254%
Run 2: Concentrate grade
optimised
0.244%
Mass pull
1.09%
0.57%
Niobium recovery
75.3%
52.4%
Nb2O5 in concentrate
9.95%
22.3%
Head grade Nb2O5
Table 1: Flotation results carried out on 10-tonne bulk sample
Locked Cycle Test Comparison
In October 2022 Auralia Metallurgy, a Perth based metallurgical testing laboratory, carried out locked
cycle tests on various core samples. A master composite sample covering the life of mine core was
collected, milled, and supplied by Globe to Auralia Metallurgy.
The results of the locked cycle tests are set out below.
Project
Composite
Test No
Grind Size
Cell Size
Product
Mag Con
Deslime O/F
Cln 4 Con
Ro/Scav Tail
Calc'd Head
GLOBE - KANYIKA
Master Comp 1
AM95-94
P100=150µm
4.4L Cell
3.0 kg
Weight
Gram
%
110.5
1.3
358.4
4.1
122.4
1.4
8212.7 93.3
8804.0 100.0
WATER
GRIND TIME
PULP DENSITY
GRINDING MEDIA
Nb2O5
%
%dist
0.17
0.5
0.41
4.3
17.76
64.7
0.12
30.4
0.38 100.0
Fe2O3
%
%dist
68.65
20.7
4.33
4.2
15.08
5.0
3.13
70.1
4.17 100.0
10/02/2022
DI Water
~34% solids
Stainless Steel
ZrO
%
%dist
0.08
0.6
0.10
2.4
7.85 62.9
0.06 34.0
0.17 100.0
Ta2O5
%
%dist
0.01
0.5
0.02
3.5
0.75 40.4
0.02 55.6
0.03 100.0
Table 2: Locked cycle test results on a master composite of core
The concentrate grade in this test was 17.8% Nb2O5 while the overall recovery was 64.7% starting with
an ore head grade of 0.38% Nb2O5. The locked cycle concentrate grade and recoveries are between the
two bulk sample results as referred in Table 1. The bulk sample results are lower due to the lower ore
head grade of only 0.24% Nb2O5.
When selecting the location for taking the bulk sample, the following criteria were used:
•
Had to be an outcropping at surface.
•
Had to be within the initial mining area.
2
The bulk sample head grade is not too dissimilar to the Datamine orebody model data for the location
of the bulk sample (data given below or refer to Table 3). The quality of the bulk sample is sufficient for
the purpose of producing concentrate for metallurgical testing purposes.
The Datamine specifications of the bulk sample location are as follows:
Nb2O5
Ta2O5
U3O8
ZrSiO4
Density
2,836.3 ppm
99.2 ppm
56.0 ppm
3,741.4 ppm
2.25 tonnes/m3
Table 3: Datamine data for outcropping
The JORC Table 1 (refer Annexure A) is reproduced from the ASX announcement dated 19 August 2021:
“Kanyika Niobium Project – Project Feasibility and Economics”. Additional information has been
included where it pertains to the extraction of a 10-tonne bulk sample taken on 27 April 2023 at an
outcropping located in the initial mining pit using an excavator. This sample was transported to a
crushing plant in Lilongwe. After crushing, the sample was sent to Energy Densification Systems in
Johannesburg, South Africa for further testing that is reported on in this announcement.
Image: Flotation testwork being undertaken at Geolabs laboratory in Johannesburg, South Africa
3
Grant Hudson, Globe’s CEO commented:
“We are incredibly pleased with the progress made in the metallurgical testwork that is underway. The
physical production of a high-quality niobium concentrate as feedstock for the refinery pilot plant is
progressing well. The demonstrated recovery of high-quality niobium and tantalum oxides are
fundamental steps towards the negotiation and finalisation of offtake agreements, as well as the
opportunity to finalise the updated feasibility study. Globe is particularly pleased with the development
of the overall Kanyika Project. We look forward to the further results of the chlorination extraction
testwork and the development and operation of the refinery pilot plant, which will be reported on
shortly.”
Next Steps
The next steps in Globe’s chlorination refinery pilot plant journey are:
•
Niobium/tantalum will be extracted and separated using environmentally sustainable
chlorination refining.
•
Levels of radiation through the refining process in the niobium/tantalum will be
confirmed.
•
Construction of a pilot plant will be initiated to produce marketing samples for the
finalisation of key offtake agreements.
Technical Partners
As previously announced2, Globe is very proud to be working closely with its key technical service
providers in the development of its concentrator and refinery development journey. These providers
are as follows:
• Geolabs https://www.geolabsglobal.com/ in the flotation testwork and production of
concentrate for feed to the refinery pilot plant operation;
• Solo Resources https://www.soloresources.co.za/ in the development of the engineering and
design of the concentrator; and
• TCM Research and the Resonant Group https://www.resonant.co.za/ in the chloride refining
metallurgical testwork and the design, construction, and operation of the chloride refinery pilot
plant.
Sales and Marketing
Globe is focused on the production of high purity niobium oxides and will therefore not be competing in
the mainstream ferro-niobium market. The high-purity niobium oxide products will be sold into the
specialty metals markets, realising premium prices over the ferro-niobium market. The oxide market
includes all oxide grades from standard grade up to optical grades of 99.98% niobium pentoxide, thus
facilitating prices over US$50/kg.
2 Refer to ASX Announcement titled ‘Quarterly Activities/Appendix 5B Cash Flow Report’ made on 31 July 2023
4
ESG
Niobium (Nb) is on the US and European critical mineral lists and has many applications in the new
economy. In its ferroniobium form it is used to produce high strength, low alloy steels that are utilised
for bridges, high-rise buildings, offshore platforms, oil and gas pipelines, automobiles, and many other
functions and structures.
Standard niobium oxide is used in the anodes of fast charging batteries, allowing for a charge to 100%
in less than 10 minutes. These batteries have utility in large vehicles that cannot afford an excessive
charging time. These include haul trucks, trains, front-end loaders, and underground mining machinery.
They are also used in batteries for handheld tools where fast charging is a notable advantage.
High purity niobium is an integral component of daily-use, energy-related, and specialty technologies
such as superalloys (which are used in aircraft engines, rocket assemblies, and other technology), and
superconducting magnets (which are used in medical imaging devices and nuclear power generation).
The Kanyika Project has been shown to be a bottom quartile cost project and is designed to ensure the
production of “green niobium” in that its Scope 1 and Scope 2 carbon emissions are set to be the lowest
in the world. Hydroelectric and solar power will comprise the majority of its power sources for both the
mine site and the refinery. The particularly low carbon footprint is also supported by a unique closedcycle chlorination refining process, which is transformative for the industry.
Project Overview
Kanyika has the potential to become the first new globally significant niobium mine in 50 years, with an
average nameplate production of 3,267 tonnes per annum (tpa) of niobium pentoxide, (Nb2O5) and 136
tpa of tantalum pentoxide (Ta2O5) over the 27-year life of operations. The Nb2O5 and Ta2O5 products
will be high-specification high-purity products with grades exceeding 99.5% and 99% respectively.
Following its optimisation study, Globe has initiated the construction of a chlorination refinery pilot
plant. The chlorination technology has a low environmental impact and low carbon footprint – which is
important to Globe’s operating philosophy. The pilot plant will be constructed and operated over the
next few months and will produce very high purity – 99.98% (optical grade) niobium pentoxide, which
will be provided to Globe’s key off-takers to assess. Once the oxide product is produced, Globe will be
keenly positioned to finalise its discussions with key industry off-takers, a major step forward in the
development of the Kanyika Project.
Authorisation for Release
This announcement has been authorised for release by the Company’s Chief Executive Officer, Grant
Hudson.
For further information, please contact:
Grant Hudson
Chief Executive Officer
+61 8 6118 7240
gh@globemm.com
Paul Smith
Chief Executive Officer Designate
+61 8 6118 7240
paul.smith@globemm.com
5
Competent Person Statement
Kanyika Niobium Project – Process Metallurgy
The technical information in this report that relates to process metallurgy is based on work completed
by TCM Research Ltd and information reviewed by Mr Rex Zietsman, who is the Chief Technology Officer
and an employee of Globe Metals & Mining Ltd. Mr Zietsman is a registered professional engineer (Pr
Eng) with the Engineering Council of South Africa, registration number 20140376, and has sufficient
experience that is relevant to the type of processing under consideration and to the activity being
undertaken to qualify as a Competent Person as defined by the JORC Code 2012. Mr Zietsman consents
to the inclusion in the report of the matters based on his information in the form and context in which it
appears.
About the Kanyika Niobium Project
The Kanyika Niobium Project is located in central Malawi, approximately 55km northeast of the regional centre of
Kasangu and is secured by Large-Scale Mining Licence No. LML0216/21 which grants the Company security of
tenure and the right to mine niobium, tantalum, and deleterious uranium.
Drilling programs totalling 33.8 kilometres of percussion and core drilling have defined the extent of
mineralisa�on. Structured and progressive engineering studies have resulted in the current (JORC 2012) Mineral
Resource Es�mate (refer below) and have given rise to significant improvements and simplifica�ons in the process
flowsheet.
In addi�on, Globe has undertaken substan�al metallurgical op�misa�on work and commissioned the pilot plant
design to demonstrate and further op�mise metallurgical processes. Metallurgical op�misa�ons studies have
improved recoveries from 62% in 2012 to 75% presently, through novel patented metallurgical processes.
The Kanyika opera�ons will produce a pyrochlore mineral concentrate that contains both niobium and tantalum in
commercially valuable volumes to be shipped to a refinery for advanced processing into high purity materials.
6
A Mineral Resource Es�mate for the Kanyika Niobium Project under the 2012 JORC guidelines was reported to
ASX on 11 July 2018 as follows:
Table 1: MRE for KNP using a 1,500 ppm Nb2 O5 lower cut
Category
Resource
(Mt)
Measured
5.3
Indicated
47
Nb2 O5 (ppm)
Table 2: MRE for KNP using a 3,000 ppm Nb2 O5 lower cut
Resource
(Mt)
Nb2 O5 (ppm)
Ta2 O5 (ppm)
Category
Ta2 O5 (ppm)
3,790
180
Measured
3.4
4,790
220
2,860
135
Indicated
16.6
4,120
160
Inferred
16
2,430
120
Inferred
2.8
4,110
190
TOTAL
68.3
2,830
135
TOTAL
22.8
4,220
190
Mineral Resource Es�mates
The informa�on in this report that relates to Mineral Resources is extracted from the report �tled “Kanyika Niobium Project –
Updated JORC Resource Es�mate” released to the Australian Securi�es Exchange (ASX) on 11 July 2018 and available to view
at www.globemm.com and for which Competent Persons’ consents were obtained. Each Competent Person’s consent remains
in place for subsequent releases by the Company of the same informa�on in the same form and context, un�l the consent is
withdrawn or replaced by a subsequent report and accompanying consent.
The Company confirms it is not aware of any new informa�on or data that materially affects the informa�on included in the
original ASX announcement released on 11 July 2018 and, in the case of es�mates of Mineral Resources, that all material
assump�ons and technical parameters underpinning the es�mates in the original ASX announcement con�nue to apply and
have not materially changed. The Company confirms that the form and context in which the Competent Persons’ findings are
presented have not been materially modified from the original ASX announcement.
Full details are contained in the ASX announcement released on 11 July 2018 �tled “Kanyika Niobium Project – Updated JORC
Resource Es�mate” available to view at www.globemm.com.
7
ANNEXURE A
Section 1 Sampling Techniques and Data
Criteria
Sampling
techniques
Drilling
techniques
Drill sample
recovery
Logging
JORC Code explanation
Nature and quality of sampling (e.g. cut channels, random
chips, or specific specialised industry standard measurement
tools appropriate to the minerals under investigation, such
as down hole gamma sondes, or handheld XRF instruments,
etc.). These examples should not be taken as limiting the
broad meaning of sampling.
Include reference to measures taken to ensure sample
representation and the appropriate calibration of any
measurement tools or systems used.
Aspects of the determination of mineralisation that are
Material to the Public Report.
In cases where ‘industry standard’ work has been done this
would be relatively simple (e.g. ‘reverse circulation drilling
was used to obtain 1 m samples from which 3 kg was
pulverised to produce a 30 g charge for fire assay’). In other
cases, more explanation may be required, such as where
there is coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of detailed
information.
Drill type (e.g. core, reverse circulation, open-hole hammer,
rotary air blast, auger, Bangka, sonic, etc.) and details (e.g.
core diameter, triple or standard tube, depth of diamond
tails, face-sampling bit or other type, whether core is
oriented and if so, by what method, etc.).
Method of recording and assessing core and chip sample
recoveries and results assessed.
Measures taken to maximise sample recovery and ensure
representative nature of the samples.
Whether a relationship exists between sample recovery and
grade and whether sample bias may have occurred due to
preferential loss/gain of fine/coarse material.
Whether core and chip samples have been geologically and
geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining studies
and metallurgical studies.
Commentary
On 27 April 2023, a ~11t bulk sample was collected at an outcropping located in the initial mining pit using an excavator.
The sample was loaded onto a tipper truck and transported to a crushing plant in Lilongwe. Here most of the sample was
crushed to -40mm. The crushed ore was loaded into bulk bags. The taking and primary crushing of the bulk sample was
witnessed and supervised by two geologists from the Malawi Geological Survey who took samples for their own use. This
sample was sent to Energy Densification Systems in Johannesburg, South Africa for further testing.
The location selected was at outcroppings of the orebody that had already been determined by drilling.
The location selected was at outcroppings of the orebody that had already been determined by drilling. The sample was
a mixture of both weathered and fresh material.
An excavator dug a pit at the selected location. Topsoil was removed and set aside before taking both surface rocks as
well as ore down to a depth of approximately 2.5m.
Not applicable – bulk sample taken.
Not applicable – bulk sample taken.
Not applicable – bulk sample taken.
No logging was carried out as this was a bulk sample.
1
Criteria
Sub-sampling
techniques and
sample
preparation
JORC Code explanation
Whether logging is qualitative or quantitative in nature.
Core (or costean, channel, etc.) photography.
The total length and percentage of the relevant
intersections logged
Commentary
See above.
If core, whether cut or sawn and whether quarter, half or all core
taken.
Not core.
If non-core, whether riffled, tube sampled, rotary split, etc. and
whether sampled wet or dry.
Sample was loaded onto a tipper truck and transported to Lilongwe. The sample was then put through a conventional
closed circuit crushing circuit. Prior to crushing, the crushing plant was brushed out and cleaned by operators to limit
contamination. 9.5t of crushed material was put into 9 bulk bags and exported to South Africa. 8 of the bags had -40mm
material while the 9th bag had the remaining +40mm that was cleaned out of the crusher.
One sample of the -40mm material was taken and a wet feed PSD conducted to find the particle size distribution. The
material had a maximum size >26.5mm and <37.5mm (more than half of the feed size was within this size range) with an
interpolated F80 of approximately 33.425mm. See report: TEST WORK REPORT, Globe Metals & Mining – Niobium Ore;
Compiled By: Boaz Friedland, Technical Director at EDS, 26 June 2023. All 33 subsequent tests were also separated using
a wet feed screening process to provide data for the appropriate sizing of the EDS multishaft mill.
3.6t of the -1mm crushed ore from EDS was transported to Light Deep Earth laboratories in Pretoria, South Africa.
The first time that the bulk sample was assayed was at Light Deep Earth. The head grade of Nb2O5 was lower than the
Mineral Resource block model estimated Nb2O5 grade of 0.2836% at the bulk sample location.
A 24 kg representative sample was extracted from the 3.6t ROM material using a bulk rotary splitter. The sample was split
into various fractions including one that was analysed with QEMSCAN – PMA (for characterisation), XRD (for QEMSCAN
calibration) and XRF (for chemical balance with the QEMSCAN).
Stream
Nb2O5 %
ZrO2 %
Al2O3 %
SiO2 %
CaO %
Fe2O3 %
Na2O %
For all sample types, the nature, quality and appropriateness of the
sample preparation technique.
Quality control procedures adopted for all sub-sampling stages to
maximise representation of samples.
Not applicable.
Head
Quality of assay
data and
laboratory tests
0.24
0.31
21.5
60.4
0.88
0.8
9.95
Measures taken to ensure that the sampling is representative of the
in-situ material collected, including for instance results for field
duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain size of the
material being sampled.
The location of the outcropping was overlaid on the orebody model to confirm that it was an outcropping of the
orebody. The sample is a mix of weathered and fresh material.
The nature, quality and appropriateness of the assaying and
laboratory procedures used and whether the technique is considered
partial or total.
Solo Resources – Gravity Separation Test Work
3.6 tons of the -1mm milled material was delivered in bags to Light Deep Earth (LDE) in Pretoria, South Africa. LDE has ton
scale and smaller splitter units. The entire batch was split and a 24kg sample was taken for characterization and gravity
evaluation. The sample was split into various fractions including one that was analysed with QEMSCAN – PMA (for
characterisation), XRD (for QEMSCAN calibration) and XRF (for chemical balance with the QEMSCAN).
Not applicable as an 11t bulk sample was taken.
The aim of the LDE test work was to provide Solo Resources (Concentrator plant designer) with options to consider for
the gravity pre-concentration of the ore. The bulk of the test work showed that gravity separation using spirals would not
be economically feasible. The full report is:
TEST WORK REPORT TO GLOBE METALS
SPIRAL AND SCRUBBING CHARACTERISATION
ISSUED BY
: Solo Resources (Pty) Ltd
REPORT DATE
: 12th October 2023
PROJECT NUMBER
: SRF 306.1 Rev 0
2
Criteria
JORC Code explanation
For geophysical tools, spectrometers, handheld XRF instruments,
etc., the parameters used in determining the analysis including
instrument make and model, reading times, calibrations factors
applied and their derivation, etc.
Nature of quality control procedures adopted (e.g. standards,
blanks, duplicates, external laboratory checks) and whether
acceptable levels of accuracy (i.e. lack of bias) and precision have
been established.
Commentary
Gravity test work samples were analysed by Light Deep Earth using QEMSCAN – PMA (for characterisation), XRD (for
QEMSCAN calibration) and XRF (for chemical balance with the QEMSCAN).
Samples were prepared and analysed at SANAS ISO/IEC 17025 accredited UIS Analytical (Pretoria, South Africa). The
analytical method used was XRF spectroscopy following a lithium metaborate fusion. The pertinent elements analysed
were Nb, Ta, Fe, Ti, U and Zr with each reported in oxide %. Loss on ignition (LOI) is determined gravimetrically at 1000˚C
degrees. he analytical methods used were QEMSCAN – PMA (for characterisation), XRD (for QEMSCAN calibration) and
XRF (for chemical balance with the QEMSCAN). The pertinent elements analysed were Nb, Ta, U and Zr.
Checks (repeat analysis and duplicates samples) were completed as part of the determination of the chemical composition
of the samples.
Analysis of standards is included for every batch of samples.
No assay data was adjusted.
Verification of
sampling and
assaying
Location of data
points
Data spacing and
distribution
Orientation of
data in relation
to geological
structure
Sample security
The verification of significant intersections by either independent or
alternative company personnel.
The onsite geologist, Mr Chris Ngwena, verified that the locations of the outcropping was indeed part of the orebody.
The use of twinned holes.
Documentation of primary data, data entry procedures, data
verification, data storage (physical and electronic) protocols.
One pit was used to collect bulk sample.
All sampling, geological logging and assay data has been captured digitally and is stored in the Globe database.
Discuss any adjustment to assay data.
No adjustments to assay data.
Accuracy and quality of surveys used to locate drill holes (collar and
down-hole surveys), trenches, mine workings and other locations
used in Mineral Resource estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
As the pit was of the order of metres in diameter, the pit was positioned using a GPS instrument.
Data spacing for reporting of Exploration Results.
Not applicable as a pit was dug where the outcropping occurred.
Whether the data spacing and distribution is sufficient to establish
the degree of geological and grade continuity appropriate for the
Mineral Resource and Ore Reserve estimation procedure(s) and
classifications applied.
Whether sample compositing has been applied.
Whether the orientation of sampling achieves unbiased sampling of
possible structures and the extent to which this is known,
considering the deposit type.
Not applicable as a pit was dug where the outcropping occurred.
If the relationship between the drilling orientation and the
orientation of key mineralised structures is considered to have
introduced a sampling bias, this should be assessed and reported if
material.
The measures taken to ensure sample security.
The bulk sample pit was dug at an outcropping located near the middle of the portion of orebody that will be mined
initially.
Coordinate system - WGS84 UTM zone 36S.
GPS elevation formed part of the topographic control.
No compositing was undertaken.
The bulk sample was excavated to approximate a cube of the mineralized material to mimic the anticipated mining
method via open pit methods.
Individual samples were packaged into plastic containers, suitably marked, and delivered to UIS Analytical by a
representative from TCM Research.
3
Criteria
Audits or reviews
JORC Code explanation
The results of any audits or reviews of sampling techniques and
data.
Commentary
None carried out.
Section 2 Reporting of Exploration/ Metallurgical Results
Criteria
Mineral
tenement and
land tenure
status
JORC Code explanation
Type, reference name/number, location and ownership including
agreements or material issues with third parties such as joint
ventures, partnerships, overriding royalties, native title interests,
historical sites, wilderness or national park and environmental
settings.
The security of the tenure held at the time of reporting along with
any known impediments to obtaining a licence to operate in the
area.
Exploration done
by other parties
Acknowledgment and appraisal of exploration by other parties.
Commentary
All of the Kanyika drilling is situated within LML0216/21, a Mining Licence, that was granted on 13 August 2021 by the
Government of Malawi, acting through the Minister of Mining to Globe Metals and Mining (Africa) Limited. The Licence
confers the Licensee the exclusive right to prospect for, mine and process, pyrochlore mineral concentrate containing
niobium and tantalum and deleterious uranium over an area of 33.42 Km2 for a period of 25 years. The Licence is defined
by UTM Zone 36S coordinates as follows:
Easting
Northing
Point
507269
8599321
A
576784
8599281
B
577172
8594317
C
570269
8594321
D
The Mining Licence is in good standing with the Department of Mines Lilongwe as at the date of this publication. The
Mining Licence has a mining lease term of 25 years from 13 August 2021 under the Mines and Minerals Act (2018) gazetted
on 1 September 2019 (and known or referred to as the Mines and Minerals Act (No8 of 2019).
From 1966 to 1967, the area was mapped at a scale of 1:250,000 by the Geological Survey of Malawi. Following mapping
no work was completed in the area until the UNDP conducted a major airborne radiometric and magnetic survey over
most of Malawi, at 1km line spacing, between 1984 and 1985. This survey led to the identification of a uranium and
uranium-thorium anomaly, measuring approximately 3km by 1km at Kanyika.
A field program to investigate the Kanyika airborne radiometric anomaly was conducted by the Malawi Geological Survey
in 1986. A total-count ground radiometric survey was completed over an area of 2 by 0.7km. Areas of high radiometric
response correlated to foliated nepheline syenite.
A total of 91 soil samples and 21 rock chip samples were taken and analysed for Nb, Zn and Pb. Chemical analyses returned
Zn and Pb results that were at or near background. Nb assays up to 1.20% in soils and 0.13% in rocks was detected,
although there was a poor correlation with anomalous radiometric zones.
The analytical suite did not include U, Zr, Ta or REEs due to limitations on available analytical equipment. Following
acquisition of the project by Globe Metals and Mining (Africa) Limited, reconnaissance field programs were initiated in
2006. A total-count ground radiometric survey defined two distinct, 020° striking parallel zones, over 2.5km strike length.
Soil and rock-chip sampling showed an associated +100ppm U3O8 soil anomaly (peak 482ppm U3O8) and coincident strong
Ta and Nb. Rock-chip samples up to 0.29% U3O8, 7.33% Nb2O5 and 0.63% Ta2O5 were returned.
4
Criteria
JORC Code explanation
Commentary
The 11 July 2018 Kanyika Niobium Project – Updated JORC Resource Estimate announcement by Globe Metals and Mining
Limited (ASX: GBE, Globe, or the Company) advised that it had completed an update of the Mineral Resources in
accordance with the 2012 JORC guidelines. The Competent Persons of this Table 1 update were Messrs. A. Stephens and
A. Bewsher and Dr. M. Steffens.
Geology
Deposit type, geological setting and style of mineralisation.
Kanyika is an intrusion-hosted Pyrochlore-Zircon mineralized deposit. It lies within the Malawi Province of the
Mozambique Orogenic Belt. It is almost entirely underlain by Precambrian and Lower Palaeozoic Basement Complex,
predominantly gneiss metamo
Share your feedback
Discover